•  Retrait en 2 heures
  •  Assortiment impressionnant
  •  Paiement sécurisé
  •  Toujours un magasin près de chez vous
  •  Retrait gratuit dans votre magasin Club
  •  7.000.0000 titres dans notre catalogue
  •  Payer en toute sécurité
  •  Toujours un magasin près de chez vous
  1. Accueil
  2. Livres
  3. Sciences humaines
  4. Sciences
  5. Reverse bias and PIN diode sensitivity. Building a solid state radiation detector

Reverse bias and PIN diode sensitivity. Building a solid state radiation detector

Gunther Klobe
Livre broché | Anglais | e-fellows.net stipendiaten-wissen | n° 1994
65,95 €
+ 131 points
Livraison 2 à 3 semaines
Passer une commande en un clic
Payer en toute sécurité
Livraison en Belgique: 3,99 €
Livraison en magasin gratuite

Description

Project Report from the year 2014 in the subject Physics - Experimental Physics, grade: Bestnote, Swiss Federal Institute of Technology Zurich (Institute for Astronomy), course: Semesterarbeit / Projektarbeit, language: English, abstract: This is a report on a research internship at the University of Oxford in the summer of 2014, which describes the final experimental steps in preparing a prototype of a solid state radiation detector based on a PIN diode. This device has multiple possible applications, e.g. it can be used to monitor cosmic radiation and space weather, which is a topic of great interest for space agencies, satellite networks, and insurance companies. The project was a success and the prototype was ready for a test flight in the end. A prototype of a solid state radiation detector based on a PIN diode has been developed to the point where it was ready for a test flight on a weather balloon. This device is intended to be used to monitor secondary cosmic radiation and may have the potential to be produced commercially since space weather is an issue of growing importance concerning the economy and technology of modern civilisation. Some of the most crucial experimental work in preparation for the test flight is discussed in this report. One important question was what reverse bias should be applied to the PIN diode. As a result, it was found that the detector's sensitivity increases with increasing reverse bias until it reaches a saturation value at ∼25V. Another concern was that the prototype may not be robust against temperature differences. This concern could be ruled out to a certain extent.

Spécifications

Parties prenantes

Auteur(s) :
Editeur:

Contenu

Nombre de pages :
24
Langue:
Anglais
Collection :
Tome:
n° 1994

Caractéristiques

EAN:
9783668257955
Date de parution :
24-08-16
Format:
Livre broché
Format numérique:
Trade paperback (VS)
Dimensions :
178 mm x 254 mm
Poids :
58 g
Librairie Club

Seulement chez Librairie Club

+ 131 points sur votre carte client de Librairie Club
CADEAU

Ticket de cinéma offert

à l'achat d'un Bongo à partir de 39 €
CADEAU
Ticket de cinéma offert
CONCOURS

Uniquement dans nos magasins : gagnez un voyage à Prague

à l'achat du nouveau Dan Brown
CONCOURS
Gagnez un voyage à Prague
RÉDUCTION

50% de réduction

sur une sélection de papeterie
RÉDUCTION
50% de réduction sur une sélection de papeterie
Standaard Boekhandel

Les avis

Nous publions uniquement les avis qui respectent les conditions requises. Consultez nos conditions pour les avis.